Features:
1. 12.1” screen with true color, wide viewing angle, high brightness LCD display.
2. HR/PR, NIBP, RR, ECG, SpO2, TEM
3. Simple and friendly operating display interface.
4. Internal chargeable large capacity battery provides convenience for patients’ moving.
5. Playback and browse function for long term waveform and monitor data record.
6. Optional printing output function, alarm triggers printing.
7. Auto double alarm with audible and visible signals
8. Anti-defibrillation, anti-interference from high frequency electric knife
9. A full-synchronistic lead multi-channel ECG display…
10. This medical equipment can be used in ICU, CCU and operation room.
Main Features
■12.1” TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
■Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
■All-round monitor for adult, pediatric and neonate.
■With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
■Finish all operations by keys and knobs.
■Maximum 8-channel waveform synchronous display.
■Display 7-lead ECG waveform on one screen, cascade ECG waveform display
■Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
■Heart rate variability (HRV) analysis function
■NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
■Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
■Drug concentration calculation and titration table functions.
■One-touch printing of trend graph
■Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
■AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
■Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).
Main Features
■12.1” TFT color LCD, 15-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
■Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
■All-round monitor for adult, pediatric and neonate.
■With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
■Waveform, parameter color and location can be set optionally.
■Operation mode: keys and buttons.
■Display up to 8-channel waveform on one screen.
■Display 7-lead ECG waveform on one screen, and with ECG step function.
■Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
■HRV analysis function.
■NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.
■Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
■Drug concentration calculation and titration table functions.
■Print trend table data with one-key.
■Connect to Central Monitoring System by 3G, WiFi or wired mode.
■AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
■Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
| Feature: |
| High resolution 12.1″color TFT display |
| Suitable for adult, pediatric and neonatal patient |
| Color TFT Screen, waveform up to 8 channels |
| Operation modes: Diagnostic, Monitor, Surgery |
| Light and portable with Built-in rechargeable lithium battery |
| UP to 10 kinds of monitor parameters |
| Arrhythmia analysis, pace-marker detection and S-T Segment analysis |
| 72 hour storage and review of trend grams and tables |
| 500 NIBP measurement date can be storage and recall |
| Electro surgical unit and defibrillation protected |
| Networkable with central monitoring system |
| Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate, Thermal Printer, CO2, IBP |
| ECG |
| 5-lead or 3-lead selectable |
| Input: 5-lead |
:RA; LA; RL; LL; V or R; L; N; F; C |
| ECG waveforms of 7-leads display on the same screen |
| Lead selection |
:I; II; III; avR; avL; avF; Vx |
| ECG waveform |
:2 channels |
| Gain selection |
:12.5mm/s, 25mm/s, 50mm/s |
| Accuracy |
:±1bpm or ±1%, whichever is greater |
| Protection |
:Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation |
| Calibration signal |
:1mV±5% |
| Alarm range: Adult |
:15-300bpm |
| Pediatric/Neonatal |
:15-350bpm |
| Arrhythmia analysis and S-T segment analysis |
| Alarm range |
:-2.0mV~2.0mV |
| S-T segment detection Measurement rang |
:-0.2mv~2.0mv |
| Alarm |
:Yes, audible and visual alarm, alarm events review |
| Operation modes |
:Manual/Automatic/STAT |
| Measurement unit |
:mmHg/KPa selectable |
| Measurement types |
:Systolic, Diastolic and Mean |
| Over-pressure protection |
:YES |
| Resolution |
:1mmHg |
| Accuracy |
:Mean error and standard deviation per ANSI/AAMI SP-10 |
| Alarm |
:Systolic, Diastolic, and Mean |
| Auto measure time |
:Adjustable |
| Measurement rang |
:10-270mmHg |
| 500 NIBP measurement date can be storage and recall |
| SpO2 |
| Measurement range |
:0-100% |
| Accuracy |
:70-100%, ±2% 0-69%, upspecified |
| Alarm range |
:0-100% Pulse rate |
| Range |
:20-254bpm |
| Accuracy |
:±3bpm |
| Method |
:RA-LL impedance |
| Pediatric/Neonatal |
:6-150rpm |
| Alarm range: Adult |
:6-120rpm |
| Pediatric/Neonatal |
:6-120rpm |
| Apnea alarm |
:YES |
| Channel |
:Dual-channel |
| Alarm range |
:0-50℃ |
| Apnea |
:0.1℃ |
| Method |
:Thermo-dilution |
| Measurement range |
:CO: 0.1-20 lit /min. |
| Channel |
:2 channels |
| Pressure transducer |
:Sensitivity: 5(mV/V/mmHg) |
| Transducer sites |
:ART, PA, CVP, RAP, LAP, ICP |
| Alarm range |
:-10~300mmHg |
| Standard Accessories: |
| ECG, SPO2, NIBP, 1- Skin TEMP |
| Optional Accessories: |
| IBP, CO2 |
Features:
1.8.4 color TFT display
2.Suitable for adult, pediatric and neonatal patient
3.Basic parameters (ECG, SpO2, NIBP) in a durable case for bedside monitoring and transport monitotring
4..Audible and visual alarms with adjustable alarm ranges
5..Networkable with CONTEC central monitoring system
6..Powerful data management and storage capacity
ECG
1.Lead type:5-lead
2.Input: RA; LA; RL; LL; V
3.Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
4.Accuracy: ±1bpm or ±1%, whichever is greater
5.Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
6.S-T detection: YES, Arrhythmia analysis: YES
7.Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
1.Method: Oscillometry
2.Operation modes: Manual/Automatic/STAT
3.Measurement unit: mmHg/KPa selectable
4.Measurement types: Systolic, Diastolic, Mean
5.Over-pressure protection: YES
SpO2
Measurement range: 0-100%
Accuracy: ±2digit (70~100%);
0~69% unspecified
Respiration
Method: RA-LL impedance
Pediatric/Neonatal: 6-150rpm
Alarm range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Apnea alarm: YES
Temperature
Resolution: 0.1
Channel: Dual-channel
Alarm range: 0-50
Optional:
2-IBP,ETCO2,Thermal Recorder